Automatic coolant refill: cost of manual refilling

Written by Jonas Albergatti | Nov 26, 2026, 7:50:28 AM

Refilling coolant by hand only takes a few minutes per machine. With many machines, it adds up. In a Liquidtool customer shop with 9 CNC machines, refilling took around 1 hour per day before automation. On top of that come costs you do not see right away. This article explains where they come from, how automatic coolant refill works and when it pays off.

What is automatic coolant refill?

With automatic coolant refill, a system takes over the work that someone would otherwise do by hand. A sensor at the machine measures how full the tank is and how high the concentration is. When coolant is missing, a dosing unit mixes water and concentrate in the right ratio and refills the tank. You no longer have to measure, mix and carry buckets every time you refill.

Why coolant tanks need constant refilling

Water-miscible coolant is mostly water. The concentrate usually makes up 7 to 12%. During production, the tank keeps losing fluid in two ways:

  • Water evaporates. The concentrate hardly evaporates and stays in the tank. This raises the concentration.
  • Coolant sticks to chips and parts or is lost through splashing and mist. Here, water and concentrate are lost together.

How much water and how much concentrate is lost differs from machine to machine and from day to day. If you always refill at the target concentration, you also add concentrate for the water that has evaporated. Over time, the concentration gets too high. But refilling with plain water is never right: it does not replace the concentrate that sticks to chips and parts. The refill mix therefore always needs concentrate, at least 0.5%. A measurement before every refill shows how high its concentration needs to be. Our guide to coolant monitoring explains how to measure.

What manual refilling costs

Labor time is the obvious part. Additional costs come from wrong concentrations, temperature jumps or overflowing tanks. Figures from Liquidtool customer shops show this.

Too much concentrate

If the concentration is too high, you use more concentrate than you need. In one Liquidtool customer shop, the coolant also left sticky oil residue on the machine and its windows. If a tank overflows, mixed coolant is lost as well. If you keep the concentration under control, you need less concentrate. In one Liquidtool customer shop, concentrate costs even fell by half after automation.

Shorter coolant life

The concentrate is formulated to protect the coolant against bacteria and fungi. If the concentration stays too low, this protection is no longer enough. Germs multiply, the pH drops and the coolant starts to smell. Then it has to be replaced sooner. In one Liquidtool customer shop, the coolant has lasted twice as long since automation, 2 years instead of 1. Every change causes costs for concentrate, disposal and cleaning. On top of that comes machine downtime.

Tools and scrap

If the concentration is too low, the coolant lubricates less well and tools wear faster. If it keeps changing, cutting conditions also change from day to day. In one Liquidtool customer shop, tools for a stainless steel part have lasted around 20% longer since automation, and scrap has fallen from 6% to below 2%.

Temperature

If you add a lot of cold coolant at once, the tank cools down sharply. Part and machine cool down with it and change their dimensions slightly. With tight tolerances, that is enough to matter. In one Liquidtool customer shop, the tank temperature dropped from 25 °C to 15 °C during refilling. This directly affected the dimensional accuracy of parts within a batch, and corrections were needed until the tank temperature was even again.

Overflows and skin contact

If you fill by eye, you risk an overflowing tank. Before automation, one Liquidtool customer shop had an overflow once or twice a year and had to do a major cleanup each time. And if you mix and carry coolant by hand, it easily gets on your skin. The Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA) calls avoiding constant skin contact with coolant the first rule of skin protection, among other things through automated systems (IFA, skin protection).

Worked example: 9 machines, one shift

In the Liquidtool customer shop with 9 CNC machines from the introduction, every machine was refilled by hand each morning before automation, without measuring the concentration first. This took around 7 minutes per machine. According to the shop's success story, this work is no longer needed today. This is how the labor cost adds up:

ItemCalculationResult
Time per day9 machines × 7 minutesabout 1 hour
Time per year1 hour × 220 production days220 hours
Labor cost per year220 hours × EUR 50EUR 11,000

The 220 production days are an assumption. EUR 50 per hour is rounded from the average labor cost in German manufacturing in 2025 (EUR 49.50, Destatis). Not included is what the shop gained in addition after automation: the coolant lasts twice as long, and tools last 15 to 20% longer.

For your shop, calculate: number of machines × minutes per machine per day × production days ÷ 60 × hourly rate.

Is a coolant mixer at the drum enough?

Some shops use a mixer at the drum. It always mixes water and concentrate at the set ratio. You still have to measure the concentration, work out what each machine needs and fill in the coolant yourself. Because a different amount of water evaporates in every tank, each machine needs a different refill mix. You would have to readjust the mixer every time. An automatic system, by contrast, measures first and refills each machine so that it keeps its target concentration.

How AUTOPILOT works

AUTOPILOT is Liquidtool's coolant automation for CNC machines. The system measures, mixes and refills automatically. It consists of two devices and is controlled with the MANAGER software:

  • SENSOR: sits at the machine tank and checks concentration, temperature and level several times a day.
  • SMARTFILLER: sits on the drum, is connected to the water supply, mixes water and concentrate and refills every connected machine. It sends a notice before the drum is empty.
  • MANAGER: software that shows all data, sends alerts and documents every refill.

One drum for several machines

One SMARTFILLER supplies several machines through piping. In MANAGER, you set a separate target concentration for each machine, for example depending on material or machining. AUTOPILOT measures and refills several times a day, always only as much as needed. Because only a small amount is added each time, concentration and temperature stay stable.

Several safeguards prevent a tank from overflowing: fill limits, a daily volume limit, monitoring of the coolant filled in and a double level measurement (hydrostatic and ultrasonic). If needed, you can still fill the tank by hand at any time. AUTOPILOT does not measure pH. You still check it separately.

When does automatic coolant refill pay off?

Above all in these cases:

  • Several machines run on the same coolant.
  • Machines run in the evening, at night or on weekends without staff. In one Liquidtool customer shop, machines stopped now and then during unattended shifts because nobody had checked the coolant in time (see also coolant management for the ghost shift).
  • Parts have tight tolerances or are sensitive to temperature.
  • Nobody knows how much coolant each machine uses.

You do not have to switch all machines at once. Several Liquidtool customers started with one machine and then equipped more step by step, see our success stories. You can test AUTOPILOT on your own machines for 90 days, and you will find the prices on the pricing page. Request a demo and we will show you how AUTOPILOT works on your machines.